Here are some videos demonstrating various set up procedures for configuring your 2404 controller.
Thanks for visiting our website. If we can be of any assistance to you, please give us a call: (205) 988-5842.
Input Configuration for Eurotherm 2404 Controller
This video demonstrates how to select the input type (Thermocouple, RTD, Millivolt, Milliamp or Volts) for the controller.
Output Set Up for Eurotherm 2404 Controller
This video demonstrates how to select an output (Heat, Cool, Raise, Lower, etc.).
Offset Tutorial for Eurotherm 2404 Controller
This demonstration is for how to set an offset to the temperature input.
4-20 mA Set Up, Eurotherm 2404 Controller
This video demonstrates how to configure a 4-20 mA input.
Access Levels Tutorial for Eurotherm 2404 Controller
Here’s a tutorial for how to access the different levels for configuration.
Here is some additional information regarding the 2404 controller.
- Versatile, high stability temperature or process controllers
- Self-tuning with overshoot inhibition
- Setpoint programmer providing up to 20 programs of 16 segments
- Heating and cooling outputs
- Modular hardware
- Customized operator display
- Digital communications
The 2404 1/4 DIN unit is a high stability controller with an extensive range of options. Either PID, ON/OFF or Motorized valve control can be configured, satisfying both electrical and gas heating applications among others.
A setpoint programmer with up to 20 programs of 16 segments is available.
The controllers accept a range of plug-in modules, heating, cooling, or process outputs, analog retransmission, second process value input and remote setpoint.
Precise control
An advanced PID control algorithm gives stable ‘Straight-line’ control of the process. A one-shot tuner is provider to set up the initial PID values and to calculate the overshoot inhibition parameters. In addition an adaptive tuner will handle processes with continually changing characteristics.
Alarms
Up to four process alarms can be combined onto a single output. Alarms can be full scale high or low, deviation from setpoint, rate of change or load failure alarms.
Digital communications
Available with either EIA485 2-wire, 4 wire or EIA232. With industry-standard protocols including: Modbus, DeviceNet®, Profibus DP, and Eurotherm® Bisync.
Please call us at (800) 446-4316 or contact us here for more information on this controller, or any other process variable control equipment.